Extracted Ticket
Ticket Number : SUNETTICKET-590
Ticket Type : Unscheduled
Ticket Status : Closed
Ticket Summary : Degraded signal
Ticket Scope :
Ticket Opened : 20100301 5:45 UTC
Ticket Closed : 20100428 7:49 UTC
Problem Start : 20100301 1:05 UTC
Problem End : 20100304 13:30 UTC
Affected organisations:
* IRF, LTU, MIUN, UMU, SLU
----
Description:
* We are seeing a degraded signal in NR_CS1_Nvkn_h.
----
Impact:
* The following customers are affected
IRF, LTU, MIUN, SLU and UMU
----
Update:
* 20100301 5:59 UTC
Contacted IPnett.
----
* 20100301 8:32 UTC
As the signal is so low IPnett will perform an emergency
maintenance today at 18:00 UTC. First clean the fiber and if
that does not help they change the amplifier. This is
service affecting.
----
* 20100301 15:16 UTC
The intervention is planned for 16:00 UTC.
----
* 20100301 19:11 UTC
All the fibers were verified and cleaned. The amplifier was
also changed but the signal is still too low. Escalating to
our fiber provider.
----
* 20100302 10:33 UTC
The output is now at -18,9dBm from Vittersjö to Näsvik and
is close to a LOS. TDC has contacted their subcontractor and
will send an engineer out to measure the fiber.
----
* 20100303 9:47 UTC
The problem seems to be between Sundsvall and Näsvik.
----
* 20100303 10:15 UTC
TDC will measure the fiber tonight after 16:00 UTC.
----
* 20100303 16:49 UTC
Maintenance has started.
----
* 20100303 18:16 UTC
For some reason the wrong fiber was measured, a new
measurement will take place later tonight.
More updates will follow.
----
* 20100303 18:58 UTC
The technicians are on the way to start the measurements.
----
* 20100303 21:23 UTC
The measurement started.
----
* 20100303 22:19 UTC
Measurements was completed and all links except MIUN red is
up since 21:47 UTC. We are now connected to a new fiber pair
and the signal is around 3dBm higher than before.
----
* 20100303 22:48 UTC
After troubleshooting MIUN's red link is still down. We do
not see any obvious hardware errors and the current fiber is
actually better than the one before. More updates will
follow.
----
* 20100304 12:18 UTC
MIUN red is still down.
IPnett will inspect the 4200 in Sundsvall at 16:00 UTC
today.
----
* 20100304 12:35 UTC
Eltel will be on site between 13:00 UTC and 15:00 UTC today
to reseat the F10-T card in the CN4200.
----
* 20100304 13:45 UTC
The F10 cards was reseated and MIUN red service was restored
at 13:30 UTC.
----
* 20100304 14:01 UTC
We have not yet received any notice on when repairs are
going to take place. Our fiber suppliers are fully aware of
the problems.
----
* 20100312 15:06 UTC
TDC will reconnect us back from the temp fiber pair and do
new measurements tonight at 18.00 UTC.
----
* 20100312 18:30 UTC
Maintenance has started.
----
* 20100312 18:45 UTC
Maintenance completed, all services restored.
----
* 20100315 12:30 UTC
A new intervention is planned for this week to carry out
fiber measurement. Date and time to follow shortly.
----
* 20100325 9:36 UTC
Fiber measurement will be carried out on 31/3 which is
tracked in SUNETTICKET-632.
----
* 20100401 8:06 UTC
Awaiting fiber measurement results from our carrier.
----
* 20100407 10:03 UTC
Asked TDC for an update.
----
* 20100408 7:28 UTC
TDC waiting for the measurements from their supplier.
----
* 20100421 10:21 UTC
TDC have not yet got the measurements. They are working on
it.
----
* 20100423 11:23 UTC
Received the measurement files from TDC.
----
Final ticket report:
* After repair of fiber in the stretch between Sundsvall and
Näsvik, the light level has restored to normal.
----